The U.S. Department of energy (DOE) commercially available LED product evaluation and report (Commercially Available LED Product Evaluation and Reporting, CALiPER) project (prior to solid state lighting commodity test project) fourth test (September 2007 -12 months) has ended. This round of testing a total of 20 kinds of goods, of which 15 kinds of SSL lamps used in various fields, the 5 fluorescent lamps and halogen lamps, as a reference. The light source and the SSL lamp test using the radiation testing method (spectroradiometry) and abridged goniophotometer smoothness measurement method (goniophotometry), the temperature test (for the highest close to the hot lamp and closed power measurement) is also studied.
The fourth round of testing items include 5 kinds of SSL to replace the light bulb (1 branch candle lamp, large 1 T8 and 3 MR16 lights to replace the light bulb), 2 lamp, lamp and several working lights and several outdoor lighting. The results of this round of testing are slightly different: a few products disappointing performance, but also did not perform particularly prominent products, but there are many highlights.
test method
In accordance with the provisions of the inspection process lighting testing laboratory LM-79 draft standard in the whole lamp were tested, rather than the traditional test separate test lamp (lamp rating) and grade (fixture efficiency), luminaire efficiency or only measured without LED control devices and arrays of electronic components and heat sink. This is because the current measurement of LED flux array devices or no standard industry testing process, on the other hand, the performance of LED is sensitive to temperature, influenced greatly, have a substantial impact on the performance of different lighting design by using LED device or LM-79 array, so the lighting efficiency standards as the evaluation of SSL based on energy efficiency products. This round of testing, to sell the products using the lamp lamp test; and to replace the light bulb to sell products, depends on its size and test tool geometry position were measured in the standard lamp holder plug.
CALiPER test selection
The overall policy of the CALiPER project is to purchase commercially viable products and test them through distributors or other marketing channels. However, due to the purchase of a product in the market, or by other DOE SSL project commissioned by the CALiPER project also accepted a number of samples for testing, and the test report which is the sample.
Fourth round CALiPER project test results
Table 1 summarizes the performance of all fourth products in the test (including light output, light efficiency, color rendering index), in addition, to provide the basis in addition to the performance measured by LM-79, also collected data published by manufacturers to spectrophotometric analysis, as control.
Table 1 DOE SSL CALiPER third round test results summary
Photometric measurement of lamps and replacement bulbs (based on LM-79, room temperature)
DOE CALiPER test number
The total power of (W)
Light output (LM)
Efficiency (lm/W)
Correlated color temperature (K)
Color rendering index
Replacement bulb
T8 replacement bulb
07-56*
Twenty-five
One thousand and fifty-eight
Forty-two
Three thousand four hundred and ninety-four
Seventy-five
MR16 replacement bulb
07-53*
Three
Eighty-two
Twenty-seven
Three thousand and seven
Seventy-four
MR16 replacement bulb
07-59*
Nine
One hundred and thirty-three
Sixteen
Three thousand three hundred and thirty-eight
Eighty-nine
MR16 replacement bulb
07-64*
Three
Seventy-five
Twenty-six
Three thousand four hundred and fifty-eight
Seventy-four
Bulb lamp replacing lamp
07-57*
Two point two
Twenty-eight
Thirteen
Two thousand eight hundred and fifty-five
Seventy-one
Downlight
Lamp (2 "is)
07-61
Two point five
Twenty-nine
Eleven
Six thousand four hundred and one
Sixty-seven
Tunnel lamp (RGB, color temperature adjustable)
07-50**
Forty
Six hundred and seventy-two
Seventeen
Adjustable
N.A.
Operating lamp
Table lamp
07-52
Twenty
Three hundred and twenty-one
17[13.1]
Five thousand eight hundred and four
Seventy-four
Table lamp
07-54
Seven
Eighty-nine
12[9.2]
Four thousand four hundred and seventy-two
Eighty-seven
Table lamp
07-55
Ten
One hundred and forty-eight
Sixteen
Four thousand three hundred and ninety
Eighty-eight
Table lamp (CFL, 18W GU24)
07-49
Sixteen
Seven hundred
Forty-three
Two thousand eight hundred and nineteen
Eighty-one
Operating lamp
07-51***
Three point five
Eighty-nine
Twenty-six
Five thousand one hundred and forty-seven
Sixty-six
Operating lamp
07-62
Two point eight
One hundred and fifty
Forty-six
Eight thousand two hundred and four
Eighty-two
Working lamp (T5 fluorescent lamp)
07-60
Sixteen
Three hundred and sixty
Twenty-three
Three thousand eight hundred and sixty-five
Sixty
Outdoor and other lamps
Outdoor area lighting
07-43
Seventy-one
Two thousand three hundred and ten
Thirty-three
Six thousand three hundred and ninety-four
Seventy-nine
Outdoor street lamp
07-63
One hundred and seventy
Six thousand two hundred and ninety-four
Thirty-seven
Five thousand two hundred and twenty-three
Seventy-five
Outdoor wall
07-48
Fourteen
Six hundred and thirty-nine
Forty-six
Two thousand six hundred and forty-eight
Eighty-three
Corridor / wall lamp LED
07-38
Sixteen
One hundred and fifty-four
Ten
Five thousand one hundred and sixty-six
Seventy-three
Corridor / wall lamp (CFL 13W GU24)
07-39
Twelve
One hundred and ninety-nine
Sixteen
Three thousand nine hundred and fifty-six
Seventy-seven
Corridor / wall lamp (halogen lamp 20W)
07-40
Twenty-three
One hundred and seventy-four
Eight
Three thousand and eighty-five
Ninety-eight
1 in order to facilitate reading, all the output, efficiency, color temperature and color rendering index of four to five into the nearest integer. 2 07-39, 07-40, 07-48, 07-49 and 07-60 for CFL (compact fluorescent lamp), fluorescent lamp and halogen lamp test, for benchmarking. The efficiency of the 3 brackets is adjusted, and the influence of the power consumption in the closed state (assuming a daily turn-on time of 3 hours) is considered. 4 * indicates that two samples of a product are tested, and the test results are the average of the two samples. 5 07-50** products offer 6 optional color temperature (2652, 2945, 3444, 3921, 4862 and 6247 K), the power, light output and efficiency values of the table are the average of the products under the 6 conditions. RGB LED generates white light, so CRI is not available. 6 07-51*** products from the 4 can work together also can work independently in the table lamp, light output and efficiency value of single lamp independent results, 4 lamps to work together results as follows: light output: 89 LM; Efficiency: 25.7 lm/W. 7 07-62 products in the output voltage under the condition of 12VDC, the efficiency value is 54 lm/W, the actual use of adding transformer, efficiency is reduced to 85%. 8 07-38, 07-39 and 7-40 will test 3 different light sources