English: 中文版 ∷  英文版

Product News

DOE announced the fourth round of CALiPER project test results

The U.S. Department of energy (DOE) commercially available LED product evaluation and report (Commercially Available LED Product Evaluation and Reporting, CALiPER) project (prior to solid state lighting commodity test project) fourth test (September 2007 -12 months) has ended. This round of testing a total of 20 kinds of goods, of which 15 kinds of SSL lamps used in various fields, the 5 fluorescent lamps and halogen lamps, as a reference. The light source and the SSL lamp test using the radiation testing method (spectroradiometry) and abridged goniophotometer smoothness measurement method (goniophotometry), the temperature test (for the highest close to the hot lamp and closed power measurement) is also studied.

The fourth round of testing items include 5 kinds of SSL to replace the light bulb (1 branch candle lamp, large 1 T8 and 3 MR16 lights to replace the light bulb), 2 lamp, lamp and several working lights and several outdoor lighting. The results of this round of testing are slightly different: a few products disappointing performance, but also did not perform particularly prominent products, but there are many highlights.

test method

In accordance with the provisions of the inspection process lighting testing laboratory LM-79 draft standard in the whole lamp were tested, rather than the traditional test separate test lamp (lamp rating) and grade (fixture efficiency), luminaire efficiency or only measured without LED control devices and arrays of electronic components and heat sink. This is because the current measurement of LED flux array devices or no standard industry testing process, on the other hand, the performance of LED is sensitive to temperature, influenced greatly, have a substantial impact on the performance of different lighting design by using LED device or LM-79 array, so the lighting efficiency standards as the evaluation of SSL based on energy efficiency products. This round of testing, to sell the products using the lamp lamp test; and to replace the light bulb to sell products, depends on its size and test tool geometry position were measured in the standard lamp holder plug.

CALiPER test selection

The overall policy of the CALiPER project is to purchase commercially viable products and test them through distributors or other marketing channels. However, due to the purchase of a product in the market, or by other DOE SSL project commissioned by the CALiPER project also accepted a number of samples for testing, and the test report which is the sample.

Fourth round CALiPER project test results

Table 1 summarizes the performance of all fourth products in the test (including light output, light efficiency, color rendering index), in addition, to provide the basis in addition to the performance measured by LM-79, also collected data published by manufacturers to spectrophotometric analysis, as control.

Table 1 DOE SSL CALiPER third round test results summary

Photometric measurement of lamps and replacement bulbs (based on LM-79, room temperature)

DOE CALiPER test number

The total power of (W)

Light output (LM)

Efficiency (lm/W)

Correlated color temperature (K)

Color rendering index

Replacement bulb

T8 replacement bulb

07-56*

Twenty-five

One thousand and fifty-eight

Forty-two

Three thousand four hundred and ninety-four

Seventy-five

MR16 replacement bulb

07-53*

Three

Eighty-two

Twenty-seven

Three thousand and seven

Seventy-four

MR16 replacement bulb

07-59*

Nine

One hundred and thirty-three

Sixteen

Three thousand three hundred and thirty-eight

Eighty-nine

MR16 replacement bulb

07-64*

Three

Seventy-five

Twenty-six

Three thousand four hundred and fifty-eight

Seventy-four

Bulb lamp replacing lamp

07-57*

Two point two

Twenty-eight

Thirteen

Two thousand eight hundred and fifty-five

Seventy-one

Downlight

Lamp (2 "is)

07-61

Two point five

Twenty-nine

Eleven

Six thousand four hundred and one

Sixty-seven

Tunnel lamp (RGB, color temperature adjustable)

07-50**

Forty

Six hundred and seventy-two

Seventeen

Adjustable

N.A.

Operating lamp

Table lamp

07-52

Twenty

Three hundred and twenty-one

17[13.1]

Five thousand eight hundred and four

Seventy-four

Table lamp

07-54

Seven

Eighty-nine

12[9.2]

Four thousand four hundred and seventy-two

Eighty-seven

Table lamp

07-55

Ten

One hundred and forty-eight

Sixteen

Four thousand three hundred and ninety

Eighty-eight

Table lamp (CFL, 18W GU24)

07-49

Sixteen

Seven hundred

Forty-three

Two thousand eight hundred and nineteen

Eighty-one

Operating lamp

07-51***

Three point five

Eighty-nine

Twenty-six

Five thousand one hundred and forty-seven

Sixty-six

Operating lamp

07-62

Two point eight

One hundred and fifty

Forty-six

Eight thousand two hundred and four

Eighty-two

Working lamp (T5 fluorescent lamp)

07-60

Sixteen

Three hundred and sixty

Twenty-three

Three thousand eight hundred and sixty-five

Sixty

Outdoor and other lamps

Outdoor area lighting

07-43

Seventy-one

Two thousand three hundred and ten

Thirty-three

Six thousand three hundred and ninety-four

Seventy-nine

Outdoor street lamp

07-63

One hundred and seventy

Six thousand two hundred and ninety-four

Thirty-seven

Five thousand two hundred and twenty-three

Seventy-five

Outdoor wall

07-48

Fourteen

Six hundred and thirty-nine

Forty-six

Two thousand six hundred and forty-eight

Eighty-three

Corridor / wall lamp LED

07-38

Sixteen

One hundred and fifty-four

Ten

Five thousand one hundred and sixty-six

Seventy-three

Corridor / wall lamp (CFL 13W GU24)

07-39

Twelve

One hundred and ninety-nine

Sixteen

Three thousand nine hundred and fifty-six

Seventy-seven

Corridor / wall lamp (halogen lamp 20W)

07-40

Twenty-three

One hundred and seventy-four

Eight

Three thousand and eighty-five

Ninety-eight

1 in order to facilitate reading, all the output, efficiency, color temperature and color rendering index of four to five into the nearest integer. 2 07-39, 07-40, 07-48, 07-49 and 07-60 for CFL (compact fluorescent lamp), fluorescent lamp and halogen lamp test, for benchmarking. The efficiency of the 3 brackets is adjusted, and the influence of the power consumption in the closed state (assuming a daily turn-on time of 3 hours) is considered. 4 * indicates that two samples of a product are tested, and the test results are the average of the two samples. 5 07-50** products offer 6 optional color temperature (2652, 2945, 3444, 3921, 4862 and 6247 K), the power, light output and efficiency values of the table are the average of the products under the 6 conditions. RGB LED generates white light, so CRI is not available. 6 07-51*** products from the 4 can work together also can work independently in the table lamp, light output and efficiency value of single lamp independent results, 4 lamps to work together results as follows: light output: 89 LM; Efficiency: 25.7 lm/W. 7 07-62 products in the output voltage under the condition of 12VDC, the efficiency value is 54 lm/W, the actual use of adding transformer, efficiency is reduced to 85%. 8 07-38, 07-39 and 7-40 will test 3 different light sources

Scan the qr codeclose