Lighting designers must see: 100 valuable architectural design experience and data interpretation (three)

76, residential buildings should not be set up in the public housing has a boiler room, transformer room, flammable and explosive chemicals stores, but the kitchen can be set up a restaurant.

77, residential design should be taken to prevent electric shock, theft, anti fall.

78, the thermocline space exceeding two or more floors in residential buildings.

79, the construction of residential buildings on the slope, when the vertical structure and the contour, the use of a more economical way to fall.

80, the housing construction project evaluation index system table has first and two indicators.

81, 7 and above (16 m) residential must be equipped with elevators.

The highest floor residential layer 82, dormitory entrance from the ground layer height greater than 20 meters, the elevator should be set up.

83, the hospital ward building, the hotel has a multi air conditioner, more than 5 storey public building indoor staircases, shall be closed staircases (including the first layer to expand the closed staircase), design Dance Hall Auditorium and more than 3 storey building on the ground, should set up a closed staircase. Public buildings, such as the main staircase staircase is not included in the total evacuation width, can not be closed staircase.

84, the library stairs evacuation books, non book database, should be designed as a closed stairwell or stairwell, archives in setting the stairs, the door closed staircase, with not less than B fire doors.

85, the elevator should not be close to the bedroom, living room layout.

86, 12 floors and above each building shall not be less than two sets of elevators.

87, the building should not be more than 18 stairs, and should not be less than level 3.

88, 0.55M+ people per staircase width (0-0.15M) calculation, should not be less than 2 stream of people.

89, the pipeline in the safety, fire and health aspects of the mutual influence of the pipeline should not be laid in the same shaft.

90, smoke and ventilation shall not use the same pipe system.

91, the general level of the library lighting room 0.75M level - 150-200-300LX; elderly room 0.75M horizontal surface - 200-300-500LX; showroom 0.75M level surface - 75-100-150LX; reader lounge 0.75M level - 30-50-75LX.

92, kindergarten standard of illumination, activity room 150LX, room 100, dormitory 75 health isolation, 30 toilets, 20 hall.

93, the illuminance uniformity of primary and secondary schools should not be less than 0.7, the vertical illuminance should not be less than 200LX.

94, two steps are not allowed to appear in the staircase.

95, elevators and escalators can not be used as a safe exit.

96, the ground floor of the building should be at least higher than the outdoor ground 0.15M.

97, the elevator should not be surrounded by stairs, unilateral arrangement should not be more than 4 elevators, the two sides should not be more than 8 sets of elevators.

98, waiting hall depth, unilateral Taiwan residential elevator is larger than B, 1.5B or other elevator; multiple bilateral arrangement is more than B and the relative lift; and "4.5M (guest).

A minimum of 99, generally flat roof is 1:50; no 1:2, slope roofing sheathing board is expected to 1:2.5; asbestos slope 1:3; wave type metal tile gradient of 1:4 steel for 1:7.

100, more than 10 meters above the roof of the building should be placed on the roof of the roof manhole or exterior ladder.