Lighting control in architectural lighting design

1, public buildings and industrial buildings in the corridors, staircases, halls and other public places of lighting, should be centralized control, and according to the construction conditions and the use of natural lighting conditions of the District, group control measures.

2, the stadium, theaters, waiting hall, waiting hall and other public places should be centralized control, and take control measures to reduce the intensity of illumination or light.

3, the hotel's each (sets) rooms should be set up energy-saving control switch.

4, residential buildings with natural lighting staircase, corridor lighting, in addition to emergency lighting, the use of energy-saving self extinguishing switch.

5, the number of the light source should not be too much. The number of switches in each room shall not be less than 2 (except for only 1 light sources).

6, room or place with two or more lamps, should be grouped according to the following control:

1) the control light is parallel to the side window;

2) production sites grouped according to workshop, workshop or process;

3) classroom, conference hall, multi-function hall, lecture hall and other places, according to the group near or away from the podium.

7, conditional place, should adopt the following control mode:

(1) a place where natural lighting is good, according to the illuminance of the place;

2, the use of personal office, the use of human induction or static induction and other ways to automatically switch lights;

3, the hotel lobby, elevator lobby and guest room corridor and other places, the use of night time to reduce the intensity of the automatic dimming device;

4 large and medium-sized buildings, according to the specific conditions of centralized or distributed, multi function or single function of the automatic control system.